SonicOS 7 Device Settings

Controlling the Management Interface Tables

The SonicWall Management Interface allows you to control the display of large tables of information across all tables in the Management Interface by changing the:

  • Number of table entries displayed on a page.
  • Frequency of background automatic refresh of tables.

Some tables have individual settings for items per page that are initialized at login to the value configured here. After these pages are viewed, their individual settings are maintained. Subsequent changes made here affect these pages only following a new login.

To change the display and refresh of tables

  1. Navigate to Device | Settings > Administration.
  2. Click Management.
  3. In the WEB MANAGEMENT SETTINGS section:
    1. Enter the desired number of items per page in the Default Table Size (items per page) field. The minimum is 1, the maximum is 5000, and the default is 50.
    2. Enter the desired refresh interval, in seconds, in the Auto-updated Table Refresh Interval (secs) field. The minimum is 1 second, the maximum is 300 seconds, and the default is 10 seconds.
  4. Click Accept.

Was This Article Helpful?

Help us to improve our support portal

Techdocs Article Helpful form

  • Hidden
  • Hidden

Techdocs Article NOT Helpful form

  • Still can't find what you're looking for? Try our knowledge base or ask our community for more help.