SonicOS 7 NSv Getting Started Guide for AWS

PAYG Installation Errors

Insufficient Interfaces

When less than two network interfaces are assigned to the EC2 instance the following error message appears on the console:

***************************************************************
NSv requires at minimum 2 ENI, power down and add addition ENI
***************************************************************

Unable to Contact Provisioning Service

When the EC2 instance cannot contact the provisioning service, the following error message appears on the console.

***************************************************************************
Cannot contact provisioning service, check that internet access is provided
***************************************************************************

To resolve this error, check

  • Does the EC2 instance have a public IP (Elastic IP) assigned?
    • If not, is it configured to access the internet by way of an internet gateway?
    • If the virtual machine is not configured to access the internet on initialization, then it is not able to acquire a serial number.
      • After initialization the EC2 instance can be isolated again.
  • Check that the security group is not blocking access to internet.
    • If it is, then the customer should enable access temporarily.
    • If they wish to restrict it, then use the IP address associated with instanceregister.soniccore.cloud.eng.sonicwall.com.