How to get alerts for WAN Failure, Firewall Reboot and VPN Up/Down Status in NSM SaaS?

Description

Alerts for WAN failures, Firewall Reboots or VPN status can be configured in NSM SaaS.

Note: 

This feature applies to NSM Advanced License. It does not apply to NSM Essential License.

Resolution

Steps to configure the alerts:

 

1. Login to NSM using https://cloud.sonicwall.com Go to to Firewalls-->Inventory-->Click on the firewall name to add alerts for, it will take us into Firewall View

Inside the Firewall VIew, Click on Monitor Tab--> Alerts & Notifications-->Add Rule: Choose Alert Type as System Events. We will see following Sub-Types under this category:

Site-To-Site VPN

Firewall Reboot

Wan Probe Failure

Cloud Secure Edge

 

Image

 

 

Example of adding WAN Probe Failure Alerts is shown below:

 

1. Click on Add Rule and choose Alert Type as System Events and Sub-Tye as WAN Probe Failure and click Next:

Image

 

2. Enable Alerts for this Notification to show up in NSM portal as well as for Emails and click Next:

Default number of days to store the History of Alerts is 10 Days.

Image

 

 

3.Summary of alert configuration will be displayed last and click Save.

Image

 

Now when there is a WAN Probe failure event on the firewall, NSM will notify via email alerts. Alert can also be viewed on NSM.

Image

 

 

Email alert will look like:

Image

 

NOTE: These alerts are available only with NSM Version 2.5 for the firewalls running on SonicOS 7.1.2. After upgrading firewall firmware to 7.1.2, Reconfigure Reporting and Analytics need to be performed in NSM in order to enable these Alert Types. 

 

Steps to Reconfigure Reporting and Analytics:Reconfigure Reporting and Analytics