This guide assumes that your NetGear FVS318 Gateway is configured with an IP of 192.168.100.1 and your SMA appliance is configured with an IP of 192.168.100.2
.
Click Remote Management from the left index of your Netgear management interface.
For the SMA appliance to function with your Netgear gateway device, you must verify that the NetGear’s management port does not conflict with the management port used by the SMA appliance.
Click Accept to save changes.
If Remote Management of the NetGear is desired, you must leave the box checked and change the default port (8080 is recommended)
To create a service definition, enter the following information:
Name | HTTPS |
Type | TCP/UDP |
Start Port | 443 |
Finish Port | 443 |
Navigate to Ports in the left navigation. Click Add.
192.168.100.2
) in the Local Server Address field.Click Accept to save changes.